PERFORMANCE
|
|
- Flow Rates Range From 3 GPM to 50 GPM or Higher
|
- Water Removal Achieve Overall Water Content As Low As 20 PPM In Multi-Pass By Removing Free, Emulsified, and Dissolved Water
|
- Particulate Removal Achieve Particle Counts As Low As ISO 14/12/9 With High Efficiency Pleated Microglass Filter Elements Rated Beta(c)>1000 per ISO 16889
|
- Entrained Air and Gas Removal Degassing via Vacuum Distillation
|
- Acid Removal Can Be Equipped With Fullers Earth or Activated Alumina Cartridges To Neutralize Acid and Lower TAN
|
- Varnish Removal Can Be Equipped With Ion Charged Bonding Cartridges To Remove Insoluble Varnish
-
|
STANDARD FEATURES
|
- Permanent Dispersion Media Inside Vacuum Tower – maximizes water extraction rates, eliminates the need for costly replacement of coalescer filter elements, and enables the system to operate effectively on high viscosity gear oils.
|
- Variable Frequency Drive – enables operator to dial in the optimal flow rate, and enhances the system overall performance during cold start-ups, on higher viscosity oils, or when a restricted inlet condition exists.
|
- Claw-Style Vacuum Pump – pulls deeper vacuum, higher CFM, and requires much less maintenance than other conventional vacuum pumps.
|
- Single Utility – requires 480V, 3-Phase electric service only, not a chilled water supply.
|
- System View Windows – enables operator to observe system operation and performance.
|
- Plugged Filter Indicator Light – positive indication when the particulate removal filter element is plugged and needs to be changed.
|
OPTIONAL FEATURES
|
|
- Inline Digital Particle Monitor
|
- Inline Digital Moisture Indicator
|
- NEMA 7 Explosion Proof Components
|
- Stainless Steel Wetted Parts
|
- 4-Point Lifting Lug Cage Structure
|
DESIGNED FOR USE ON
|
|
|
|
- Gear Oil (ISO VG 220 – ISO VG 680)
|
|
|
- Phosphate Ester (Fyrquel EHC Fluid)
|
|